Automated Uptime Layer with Smart Exchange Release 1.0.0.0 Release Notes
These Release Notes (updated 11:59 AM EST on 12/20/2024) are for Automated Uptime Layer with Smart Exchange Release 1.0.0.0. See the following sections:
New Features and Enhancements
Automated Uptime Layer with Smart Exchange Release 1.0.0.0 introduces ztC Endurance 3100, 5100, and 7100 systems running VMware ESXi and Automated Uptime Layer with Smart Exchange. See Overview of Stratus ztC Endurance Systems for more information.
Important Considerations
Important Information about VMware License Activation
Broadcom® has changed VMware licensing terms. If you need to activate a Stratus-supplied VMware perpetual license, read the information provided at the following website: https://www.stratus.com/go/vmware-activation/.
Do Not Change BIOS Settings
Do not change any BIOS settings from their default settings without first being told to do so by Stratus Customer Service.
Known Issues
Do Not Use BIOS to Disable Wake On LAN
Setting Wake On LAN
to Disabled
in the BIOS does not disable this functionality. Instead, use the VMware settings documented in https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vm_admin.doc/GUID-879FA851-2B24-49E6-B58F-F25D0E923D17.html to disable Wake On LAN.
Do Not Specify a VLAN ID During Installation
Specifying a VLAN during the VMware ESXi and Automated Uptime Layer with Smart Exchange installation is not currently supported.
During the installation, if you are using a yaml
file, enter --NONE--
for VLAN. If you are not using a yaml
file or leave that entry blank, enter none
if the script prompts for it.
Long Network Delays with PCIe Adapter During I/O Faults
If you add a PCIe adapter to an IP Hash vSwitch with the physical ports configured in a static port group, it could result in long network delays when an I/O module is being brought up.
Manual Reboot of Standby Compute Module on Which install.sh
Is Running Required to Register Hostname with DNS Server
If you are configuring a system for DHCP and want the hostname to be registered with the DNS server, perform one of the following procedures to register it with DNS.
-
Manually reboot the standby compute module on which
install.sh
(ornet_config.sh
) is run. -
Run the command
sudo netplan apply
.
Do Not Configure Management VM With Static IPv6 Addresses During Installation
If you configure the ztC Endurance Management VM with static IPv6 addresses during installation, the installation script may experience an error while attempting to verify that the IP addresses were set.
To avoid this problem, use DHCP to configure the ztC Endurance Management VM during installation. After the installation is complete, run the net_config.sh
command to configure the static IPv6 addresses.
BMC Configuration Script Incorrectly Reports IP Addresses
The BMC configuration script (/opt/stratus/bin/bmc_config.sh
) may incorrectly report that BMC B has been assigned an IP address of 0.0.0.0 for both IP addresses, even though the script has set the IP addresses correctly. This can occur if the addresses have not finished updating when the script displays them.
If you need to view the IP addresses, run the bmc_config.sh
script again.
Smart Exchange May Cause USB Driver to Issue Spurious Warnings in vmkernel.log
File
The VMware USB driver may incorrectly view a Smart Exchange operation as an error due to the hardware temporarily "disappearing" and then "reappearing." In this case, the driver may send multiple warnings to the vmkernel.log
file, similar to the following warnings. You can safely ignore these warnings.
2023-02-02T15:26:02.581Z Wa(180) vmkwarning: cpu63:2098291)WARNING: vmkusb: Retry 1 time(s) for command = 15 (0x0000000000000000, 0x00000000, 0x01013c00) 2023-02-02T15:26:02Z In(182) vmkernel: : Failure^[[0m
Vague Error Message When User Does Not Set Gateway Address
If you configure a static IP address but do not specify the gateway address in the yaml
file, the following message is displayed:
-------- ERROR --------- (None, '255.255.255.0') does not appear to be an IPv4 or IPv6 interface
In the preceding message, None
indicates that you did not specify the gateway address.
Remove Existing ASNConnect Data When Installing Replacement Compute Module
If you install a replacement compute module, contact Stratus Customer Service for instructions on removing existing ASNConnect configuration data before you install ASNConnect on the replacement compute module.
Invalid Characters in Management Daemon User Password May Cause install.sh
to Fail
If the generated management daemon user password contains an invalid character, the install.sh
script may fail, as shown in the following output:
Creating Mgmt Daemon user Enter value for 'password': --------- ERROR --------- Unable to create Mgmt daemon account on ESX
If you encounter this error, run the install.sh
script again. The script will generate a new password.
Run bmc_config
or net_config
Script Again If Network Reconfiguration Fails
If network reconfiguration fails, run the bmc_config
script or net_config
script again.
Enable Secure Boot Setting in the BIOS Setup Utility
New ztC Endurance systems may be shipped with the Secure Boot setting disabled in the BIOS setup utility. If you want this setting enabled, check this setting, and, if necessary, enable it as described in the following procedure.
To enable the Secure Boot setting in the BIOS setup utility
-
Restart the ztC Endurance system. As it starts to boot and the Stratus ztC Endurance screen appears, press either the Delete key or the Esc key.
-
From the
Main
menu of the BIOS setup utility, use the arrow keys to select theSecurity
tab. -
From the
Security
menu, look at theSecure Boot
option.-
If it is set to
Enabled
, no changes are needed and you can exit the utility. From theSave & Exit
menu, use the arrow keys to selectDiscard Changes and Exit
. SelectYes
, and press Enter. -
If it is set to
Disabled
, use the arrow keys to select theSecure Boot
option. Press Enter.
-
-
Next to
Secure Boot
, use the space bar to change theDisabled
option toEnabled
. Press Esc. -
From the
Save & Exit
menu, use the arrow keys to selectSave Changes and Reset
. SelectYes
and press Enter. -
Repeat steps 1-5 for the other compute module.
Update Stored Copy of BMC Web Console admin
Password
If someone uses the BMC Web console to change the BMC admin
password, you must update System Management’s stored copy of that password by executing the following command as root
. Otherwise, any attempts by System Management to access the BMC will fail.
cfgpasswd
command does not update the actual administrator passwords; it updates only the copies of the passwords stored in the System Management configuration file./opt/stratus/sbin/cfgpasswd --bmcadmin
The --bmcadmin
option prompts you to specify the new password for the BMC administrator account.
admin
password on both compute modules must be identical. System Management stores only one password for both BMCs. The following example shows how to use the cfgpasswd
command.
zenadmin@sys001-ztcmgmt:~$ sudo /opt/stratus/sbin/cfgpasswd --bmcadmin Stopping sra-mgmt... Enter value for BMC admin password: xxxxxxxxxxx Confirm value for BMC admin password: xxxxxxxxxxx Installed /opt/stratus/config/install-config.json Restarting sra-mgmt... zenadmin@sys001-ztcmgmt:~$
Install ASNConnect After You Replace a Compute Module
If you replace a compute module, you must contact your authorized Stratus service representative (see Getting Help) so they can remove the ASNConnect software associated with the old compute module. After that, you can install ASNConnect on the new compute module as described in Enabling ASNConnect.
ATTN LED Does Not Indicate When AC Power Cord Is Removed
For this ztC Endurance release, the ATTN LED on the control-panel ear A module located at the front right of the ztC Endurance system. It houses a USB 2.0 port, power button for the ztC Endurance system, and LEDs that indicate system power status (PWR), fault conditions (ATTN), and module identification status (UID). does not indicate when the AC power cord is removed. It only indicates when the PSU itself is removed or has failed. For more information about this ATTN LED, see Table 10.
ztC Endurance Console May Hang If Up and Down Arrow Keys Are Used
The ztC Endurance console may hang if you use the up and down arrow keys while on the Hardware page. If this occurs, use the F5 key or the refresh button to reload the page.
System Reports a PSU Error When Power State Changes From No Power to Powered On
When a ztC Endurance system goes from a state of no power to power, the ztC Endurance console may report that one or both PSUs have failed. Some examples of when this situation can occur are during the initial power-on, or if you remove both power cords from the system, reconnect them, and boot the system. As long as both PSU LEDs are solid green, there is no imminent danger, and you can address the issue at a convenient time. However, if the PSU LEDs are solid amber or blinking amber, there may be a legitimate problem with the PSUs that requires prompt attention.
If you encounter this issue:
-
If you can physically access the ztC Endurance system:
-
Check the PSU LED status. Both PSU LEDs should be solid green, indicating that the PSUs are okay. See Figure 29 and Table 12.
-
Remove the power cord from the PSU that the ztC Endurance console reported as failed. See Figure 46.
-
Wait for the LED on the affected PSU to completely turn off. See Figure 29.
-
Reconnect the power cord. See Connecting the System to Electrical Power.
-
-
If the system is remote and you cannot physically access it, contact Stratus Customer Service for assistance.
Enter Only One DNS Server During Installation
If you try to enter more than one name server for the Standby OS, ESXi host, or Management VM in the installation configuration file (zen_config.yaml
) or when prompted in the installation script, the script will not proceed until you enter only one name server. If needed, you can add a second name server after installation by using standard Ubuntu or VMware ESXi management utilities.
For the Standby OS specifically, if you earlier added one or more additional name servers and then you replace a compute module or upgrade the system software, you must manually add the additional name server(s) back to the Standby OS. You must do this because those operations reinstall the Standby OS, and any configuration operations outside those specified by the ztC Endurance installation are lost during the reinstallation.
Do Not Use Certain Special Characters in BMC Password
Do not use the special characters #
, !
, or $
in the BMC Web console admin
password. If you enter a BMC password that contains these special characters during the installation process, the installation fails with an Invalid placeholder in string
error message.
Accessing Stratus Knowledge Base Articles
For information about accessing Stratus Knowledge Base articles, see Getting Help.
Getting Help
If you have a technical question about ztC Endurance systems, see Getting Help.