System Specifications
Compute Module (Quantities listed are for each compute module) |
|
---|---|
Physical dimensions |
Maximum weight:
Length: 22.25 in. (565.2 mm) Width: 8.625 in. (219 mm) Height: 1.625 in. (41.2 mm) |
Processors |
3100: One Intel® Sapphire Rapids 2.0 GHz 12-core processor 5100: Two Intel Sapphire Rapids 2.0 GHz 12-core processors 7100: Two Intel Sapphire Rapids 2.0 GHz 24-core processors |
System memory |
RDIMM capacity: 64 GB 3100: 8 physical, DDR5 RDIMM slots. Available RDIMM configurations are 64 GB, 128 GB, or 256 GB. 5100: 16 physical, DDR5 RDIMM slots. Available RDIMM configurations are 128 GB, 256 GB, or 512 GB. 7100: 16 physical, DDR5 RDIMM slots. Available RDIMM configurations are 256 GB, 512 GB, or 1024 GB. |
Ports |
One UART (USB-C) debug port. For use by Stratus Customer Service. One VGA port Two USB 3.0 ports |
Storage Module | |
Physical dimensions |
Maximum weight: 10 lb (4.5 kg) Length: 22.25 in. (565.2 mm) Width: 8.625 in. (219 mm) Height: 1.625 in. (41.2 mm) |
Disk drives |
Up to six U.3 Non-Volatile Memory Express (NVMe) solid-state disk (SSD) drives per storage module. Available as 1.6 TB, 3.2 TB, and 6.4 TB drives. |
I/O Module | |
Physical dimensions |
Maximum weight: 5 lb (2.3 kg) Length: 11.25 in. (285.8 mm) Width: 7.125 in. (181 mm) Height: 3.25 in. (82.6 mm) |
Ports |
Per I/O module:
|
PCIe adapters |
See https://www.intel.com/ for detailed information about these PCIe adapters:
See https://www.marvell.com/ for detailed information about this Fibre-Channel PCIe adapter:
|
Control-Panel (Right) Ear | |
Port | One USB 2.0 port per system |
PSU | |
Physical dimensions |
Weight: 3 lb (1.4 kg) Length: 12.25 in. (311.2 mm) Width: 1.5 in. (38.1 mm) Height: 2.875 in. (73 mm) |
Rail Kit | |
Weight, in box | 9 lb (4 kg) |
USB Keyboard and USB Mouse | |
Physical dimensions |
Weight, in box: 2 lb (.9 kg) Depth: 8 in. (20.3 cm) Width: 19 in. (48.3 cm) Height: 2.5 in. (6.4 cm; 2U) |
U.S. Power Cords | |
Weight, in box | 2.6 lb (1.2 kg) |
AC Power | |
Input power (watts) |
3100: 1247.4W at 100V or 1425W at 200V 5100: 2970W 7100: 2970W Notice: These input power ratings are established by National Recognized Testing Laboratories (NRTL) to ensure that the product design and branch circuit supplying power can safely support operation of the product. These tests include ranges of stressful environmental operation parameters, application loading, and optional product configurations. These ratings may not reflect your specific product configuration and operational situation (that is, your system's input power may be less than these ratings), but following these ratings provides a safe installation as tested by the NRTL.
|
Nominal input voltage |
3100: 100-127V or 200-240V, 50/60 Hz 5100: 200‐240V, 50/60 Hz 7100: 200‐240V, 50/60 Hz |
Power factor | 0.99 |
Apparent Power (VA) |
3100: 1260 VA 100V (12.6A x 2) or 1440 VA 200V (7.2A x 2) 5100: 3000 VA 200V (15A x 2) 7100: 3000 VA 200V (15A x 2) |
Protective earth/ground current | 0.8 mA maximum for each AC power cord |
Thermal load |
3100: 4097 BTUs/hr 5100: 5868 BTUs/hr 7100: 6015 BTUs/hr |
Environmental | |
Operating temperature |
41° F to 95° F (5° C to 35° C) For every 800 ft (243.8 m) above 2000 ft (609.6 m), lower the maximum operating temperature by 0.56° F (1° C). |
Storage temperature | -38° F to 140° F (-39° C to 60° C), vented |
Operating altitude | 0 ft to 10,000 ft (0m to 3,048m). In China markets, regulations may limit installations to a maximum altitude of 6562 ft (2000m). |
Maximum rate of temperature change during operation | 54° F (12° C) per hour |
Relative humidity during operation | 10% to 80% (noncondensing) |
Relative humidity during storage | 5% to 95% (noncondensing) |
Maximum rate of change of temperature during storage | 68°F (20°C) per hour |
Shock |
Operating: Minimum - Fixed setting, Half-Sine wave, 2G, 10ms, 10times Non-operating: Minimum - Fixed in a rack hitting and dropping at a 15mm edge at 300mm/s x3 |
Vibration |
Operating: Minimum - Fixed setting, log sweep, 5 - 30Hz sine wave, 0.25G, 1.5min x2 (3min) all 3 axis Non-operating: Minimum - Fixed setting, 3 - 200Hz random wave, 0.59G, 30min, Z-Axis |
Physical Dimensions | |
Weight |
3100:
5100 and 7100:
|
Height | 3.429 in. (87.10 mm) |
Width | 17.559 in. (446 mm) |
Depth | 35.826 in. (910 mm) |
Acoustics (22C Room Temperature) | |
Decibels |
3100:
5100 and 7100:
|
Internal Battery | |
Lithium battery | CR2032: 445 |